Fitting of gp18M crystal structure into 3D cryo-EM reconstruction of bacteriophage T4 contracted tail
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 3FOA |
Sample |
---|
bacteriophage T4 extended tail |
Sample Components |
one disk of the tail sheath in the contracted conformation |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 1965 |
Reported Resolution (Å) | 16 |
Resolution Method | |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C6 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (3FOA) | ||||
Refinement Space | |||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | KODAK SO-163 FILM | ||||||||
Electron Dose (electrons/Å**2) | 20 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2002-01-06 |
Temperature (Kelvin) | |
Microscope Model | FEI/PHILIPS CM300FEG/T |
Minimum Defocus (nm) | 500 |
Maximum Defocus (nm) | 3400 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 45000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
MODEL FITTING | SITUS COLORES | |
RECONSTRUCTION | SPIDER |