8WG3 | pdb_00008wg3

mouse TMEM63b in LMNG-CHS micelle


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFoldQ3TWI9 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined43.445
r_long_range_B_other43.444
r_mcangle_it27.544
r_mcangle_other27.543
r_scangle_other25.959
r_dihedral_angle_2_deg18.132
r_mcbond_it17
r_mcbond_other16.996
r_dihedral_angle_3_deg16.074
r_scbond_it15.663
Sample
mouse TMEM63B
Specimen Preparation
Sample Aggregation State2D ARRAY
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles110878
Reported Resolution (Å)3.4
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)1600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.2.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONcryoSPARC4.2.1
MODEL FITTINGCoot0.9.9.8
MODEL FITTINGISOLDE1.4.3
INITIAL EULER ASSIGNMENTcryoSPARC4.2.1
FINAL EULER ASSIGNMENTcryoSPARC4.2.1
CLASSIFICATIONcryoSPARC4.2.1
RECONSTRUCTIONcryoSPARC4.2.1
MODEL REFINEMENTServalcat0.2.24
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY